The IEC 60335 requirements for glow wire tester

2015-09-11

The IEC 60335 requirements for glow wire tester 


 

According to IEC 60335 clause 30.2.2 , for appliances that are operated while attended, parts of non-metallic material supporting current-carrying connections and parts of non-metallic material within a distance of 3 mm of such connections,  are subjected to the Glow Wire Tester of IEC 60695-2-11.

 

NOTE 1 Contacts in components such as switch contacts are considered to be connections.

 

NOTE 2 The tip of the glow-wire should be applied to the part in the vicinity of the connection.

 

NOTE 3 Some applications of the term "within a distance of 3 mm" are shown in Figure O.5.

 

The test severity is:

– 750 °C, for connections that carry a current exceeding 0,5 A during normal operation,

– 650 °C, for other connections.

 

The Zhilitong Electromechanical Co., ltd supplies Glow Wire Tester ZLT-GTR, which complies with above requirements of IEC 60335 standard.

Previous : The comparison between new and old standard for glow wire tester(4)

Next : The IEC60884-1 requirements for glow wire tester

#

# # # # # # #

#