Guangzhou zhilitong Electromechanical Co.,Ltd
  Email: sales@electricaltest.com.cn, sales@electricaltest.cn   Tel: +862081600059,18022468593   QQ :   2355822502, 2355822508

Add : 3-7, 1 Floor, Block C, No.23 Panlong Industrial Zone, Longxi Road, Guangzhou, China

News&Successful Cases

The Requirements of Cord Anchorage Test Device

2016-06-27

The Requirements of Cord Anchorage Test Device


Based on IEC 60884-1 clause 23.2, The effectiveness of the retention of the cable by the cord anchorage is checked by the following test by means of Cord Anchorage Test Device.

 

The flexible cable is subjected for 1 min to a torque as specified intable 18, applying torque to the position as close as possible to the specimen.

 

Table 18 – Torque test values for cord anchorages


Rating of plug or portable socket outlet        Flexible Cable 

   2x 0.5  2x0.75  3x0.75  3x0.75 (2 or more) x 1  
       Up to and including 16A and                      250V   0.10Nm   0.15Nm   0.15Nm   0.25Nm   0.25Nm 
 16A and above 250V   -  -  -  -  0.35Nm 
 Above 16A   -  -  -  -  0.425Nm 


Zhilitong Electromechanical Co., Ltd manufactures Cord Anchorage Test Device ZLT-LJ3, which are sold and accepted by many laboratory.

Previous : SGS Gulf Limited purchased IEC60335-1 Test Equipment

Next : How to use test probe 13

#

# # # # # # #

#

Copyright © Guangzhou zhilitong Electromechanical Co.,Ltd 粤ICP备12040474号 Powered by dyyseo.com