2015-07-18

How to determine if tracking test for lamp accessories is qualified ?

According to the requirements of IEC60598 standard, the qualification of tracking test for lamp accessories should be determined as below :

The specimen shall withstand 50 drops without failure at a test voltage of PTI 175.
A failure has occurred if a current of 0.5 A or more flows for at least 2s by a conducting path
between the electrodes on the surface of the specimen, and make the overcurrent relay operate , or
if the specimen burns without releasing the overcurrent relay

The  tracking tester manufactured by Zhilitong Electromechanical Co meets with above requirements of IEC60598, IEC60112.