The spring impact test for stationary cooking ranges, oven and similar appliance
As specified in IEC 60335-2-6 standard, if the external surface of stationary cooking range is made of glass-ceramic or similar material, compliance is checked by appling 3 blows to the appliance in accordance with test Ehb of IEC 60068-2-75, F22.50 Spring Hammer Impact Testing , having an impact energy of 0.5J±0.04J ,
But for hob surfaces of glass-ceramic or similar material, there blows are applied to parts of the surfaces that are not exposed to impacts during loaded vessel test of 21.102, the impact energy being increased to 0.70±0.05J
Zhilitong Electromechanical Co., Ltd supplies F22.50 Spring Hammer Impact Testing ZLT-CJ1 with single modle 0.5J or 0.7J impact energy, and ZLT-CJ3 with various model 0.2,0.35,0.5,0.7,1.0J impact energy adjustable.