The glow wire test for plug and socket outlet conform to IS 1293 2016-01-05
The glow wire test for plug and socket outlet conform to IS 1293 According to IS 1293 clause 28.1.1, glow wire tester is performed according to IS 11000 (Part 2/Sec 1) under the following conditions: — for parts of insulating material necessary to retain current-carrying parts and parts of the earthing ci...
-
The tracking test for plug and socket-outlet conform to IS 1923 2016-01-04
The tracking test for plug and socket-outlet conform to IS 1293 According to IS 1293 clause 28.2, for accessories other than ordinary, parts of insulating material retaining live parts in position shall be of material resistant to tracking tester. Compliance is checked according to IS 2824. Ceramics ...
-
The spring impact test for stationary cooking ranges, oven and similar appliance 2016-01-03
The spring impact test for stationary cooking ranges, oven and similar appliance As specified in IEC 60335-2-6 standard, if the external surface of stationary cooking range is made of glass-ceramic or similar material, compliance is checked by appling 3 blows to the appliance in accordance with test Ehb of IEC 600...
-
The Flexing Test for Surge Protective Devices 2015-12-29
The Flexing Test for Surge Protective Devices According to IEC 61643 clause 7.9.1.4, non-rewireable SPDs shall be so designed that the flexible cable or cord is protected against excessive bending where it enters the accessory. Compliance is checked by inspection and by a flexing test made by means of a flexing test sw...
-
The Mechanical Strength Test for Information Technology Equipment 2015-12-28
The Mechanical Strength Test for Information Technology Equipment According to IEC 60950 standard, equipment shall have adequate mechanical strength and shall be so constructed that no hazard is created in the meaning of this standard when subjected to handling as may be expected. Compliance is checked by tes...
-
The glow wire test for plug, socket outlets and coupler for industrial purpose 2016-01-04
The glow wire test for plug, socket outlets and coupler for industrial purpose According to IEC 60309-1 calsue 27, external parts of insulating material and insulating parts supporting live parts of accessories shall be resistant to abnormal heat and to fire. Compliance is checked by the glow wire tester given i...
-
The Tracking Test for plug and socket-outlet for household and similar purpose as per VDE standard 2015-12-24
The Tracking Test for plug and socket-outlet for household and similar purpose as per VDE standard According to VDE 0620 caluse 28.2, parts of insulating material retaining live parts in position , which IP code is higher than IPX0, is shall be of material resistant to tracking test. The test is carried out according t...
-
Glow wire test for self ballasted LED lamps for general lighting services by voltage>50V 2015-12-22
Glow wire test for self ballasted LED lamps for general lighting services by voltage>50V In the basis of IEC 62560 clause 12 , parts of insulating material retaining live part in position and external parts of insulating material providing protection against electric shock are subjected to the glow wire tester in accor...
-
The needle flame test for Audio, Video and similar electronic apparatus 2015-12-16
The needle flame test for Audio, Video and similar electronic apparatus In the basis of IEC 60065 Annex G, if no flammability category V-0 test specimens in accordance with IEC 60707, the needle flame test is made according to IEC 60695-11-5 on three specimens of end products as used in the apparatus. If flammability c...
-
The fire hazard testing for base material for printed circuit 2015-12-15
The fire hazard testing for base material for printed circuit According to IEC 60249,for single electronic component , in order to evaluate the extent of burning and the velocity of flame propagation ,i.e. The linear burning rate ( as Horizontal flame testing ) or the extent of burning after removal of the test flame &...