Required by IEC 60598 clause 13.3.2, parts of insulating material retaining current -carrying parts , SELV parts in position and parts of insulating material which do not retain live parts in position , but which provide protection against electric shock, shall withstand the test resistance to flame and ignition using glow wire tester described in IEC60695-2-10, except those cases where the insulating material is ceramic.
The glow wire tester ZLT-GTR, produced by Zhilitong Electromechanical Co., ltd, complies with above requirements of IEC 60598-1, IEC60695-2-10 standard.
Previous : What are the parts that isn’t suitable for glow wire test?