Email: sales@electricaltest.com.cn, sales@electricaltest.cn
Tel: +862081600059,18011959092
QQ : 2355822502, 2355822508
Add : 3-7, 1 Floor, Block C, No.23 Panlong Industrial Zone, Longxi Road, Guangzhou, China
News&Successful Cases
2015-10-23
The information of gas required by flammability test
The flammability test usually refer to needle flame burner test, horizontal vertical flame test and glow wire test .
And glow wire tester is carried out by heating circuit, no need to be ignited by gas.
For burning test of V - 0, V - 1 or V - 2, 5VA, 5VB class material, the gas is methane, over 98% purity.
For flammability test of HF - 1, 2 - HF or HBF class foam material, the gas is methane, with not less than 98% purity and 37+ 1MJ/m3 calorific value .
For Needle Flame Burner test, the methane with purity of not less than 98%. is used.
For horizontal vertical flame test, should use methane not less than 98% purity.
Previous : CE Certificate for Glow Wire Tester
Next : The certain parts of luminaire for needle flame burner test