Add : No.166-8 Longxi Middle Road, Liwan District, Guangzhou City, Guangdong Province, China
News&Successful Cases
2015-08-11
How to determine UL94 classed 94-5VA  testing ?
 
 As per UL94 standard, a material shall be classified 94-5VA as described as below:
 
 1 Afterflame time plus afterglow time after fifth flame application for each individual bar specimen : ≤ 60s 
 
 2 Cotton Indicator Ignited by flaming particles or drop from any bar specimen: No 
 
 3 Burn-through (hole) of any plaque specimen: No 
 
 Materials classified 5VA shall also comply with the requirements described for materials classified V-0 or V-1.
 
 Zhilitong Electromechanical Co., Ltd produces  Horizontal Vertical Flame Test Equipment , which can perform UL94 classed 94-5VA  testing.
Previous : How to determine UL94 classed V-1 testing ?
        