Add : 3-7, 1 Floor, Block C, No.23 Panlong Industrial Zone, Longxi Road, Guangzhou, China
Products
- China
- ZLT-HV50
- Guangzhou
- In 25 working days
- Ex-work , CNF , FOB
Horizontal Vertical Flame Tester
Model: ZLT-HV50
The ZLT Horizontal Vertical Flame Chamber Tester is a fully automatic instrument contained in its own cabinet to maximize the safety of the operator. It screening procedure for comparing the relative burning behaviour specimens made from plastic and other non-metallic materials ,exposed to a flame ignition source of 50W nominal power.
These test methods determine the linear burning rate and the after flame/after glow times, as well as the damaged length of specimens. They are applicable to solid and cellular materials that have an apparent density of not less than 250kg/m3,determined in accordance with ISO845.Then do not apply to materials that shrink away from the applied flame without ignition;ISO9773 should be used for thin flexible materials. And it's the combustion test device of plastic materials represented by UL 94. It can perform each test of HB, V0 to V2.
Specification :
Model
ZLT-HV50
Test Flame
50W ( burning test for V-0, V-1, V-2 classification )
Burner Tube
Internal diameter : Φ 9.5mm ± 0.3mm length: 100mm ±10mm
Burning Angle
0", 20", 45"
Thermocouple Size O/D
0.5mm
Thermocouple
Type K (Ni/Cr -Ni/Al )
Standard Copper Block
Φ 5.5mm ±0.01mm Weight : 1.76g ±0.01g before drilling Cu-ETP
Time for Temperature to increase
From 100°C ± 5°C to 700°C±3°C: 44s±2s (preset )
Overall Height of flame
18mm --22mm (adjustable )
Gas supply (do not provide )
Methane min. 98% purity
Flowmeter
105±10ml /min.
Manometer
0 KPa to 7.5 KPa
Input power
220 V 50 Hz 3 A or 115 V 60 Hz optional
Conform to standards
UL94, IEC 60695-11-4 , IEC 60695-11-10
Digital Temperature Display
Include: 50W Flame Height Gauge And 100% Absorbent Cotton.
Previous: Burning Characteristics Tester
Next: Horizontal Vertical Flame Tester ZLT-UL94
Related Products-
ZLT-GTR, to determine the fire resistance by the f...
-
Vehicle Interior Material Horizontal Fla...
Test to determine horizontal burning rate of certa... -
ZLT-GTR, accordance with IEC60695-2-10(2...
-
ZLT-ZY2P, the instrument is designed to conform to...
-
ZLT-LDQ1, determination of comparative tracking in...
-
Horizontal Vertical Flame Tester ZLT-UL9...
ZLT-UL94, the combustion test device of plastic ma... -
Burning Characteristics Tester
ZLT-HV4, applicable to the single wire and cable, ... -
Single Vertical Insulated Wire Flame Cha...
ZLT-BS1, conform to standard IEC60332-1-1,IEC60332... -
Hot Wire Coil Ignitability Test Apparatu...
ZLT-HW1, to measure the time required to ignite th... -
High Current ARC Ignition Tester
ZLT-DQY, according to UL746A,UL1082 -
High Voltage Arc Ignition Test Equipment
ZLT-HVL, according to IEC61621,ASTM... -
ZLT-ZL4, Clearance Gauge , conform to IEC 60695-11...